fbpx

Profile for “LOARA”

Produkto aprašymas

PRODUCT DESCRIPTION

The LOARA steel roof tile was created by refining the shape of the TUR panel roofing. The higher crease is an interesting continuation of the series, which is very popular among customers. The metal roofing tile is symmetrical, which makes the assembly process much easier.

module length:350 mm
embossing height:30 mm
profile height:23 mm
usable width:1120 mm
total width:~ 1187 mm
min. slope of the roof:15 sts
accessoriesscrews, gaskets, sealing collars, flashings
, touch-up paints
dedicated accessoriesstarting ventilation patch

PROTECTIVE COATINGS AVAILABLE

protective coatingscoating thicknessresistance
to corrosion
resistance
to UV
possibility of
processing
guarantee

aesthetic / technical

glossy polyester25 µm *** ****10/30 years
coarse-grained polyester mat35 µm *** ** **15/35 years
TOPMAT35 µm **** *******20/35 years
PURMAX40 µm***********20/40 years
PURLAK50 µm **** *** ***up to 30/50 years
PURMAT50 µm **** **** ***up to 30/50 years

Rating scale from * to **** – where **** means the highest grade

Check the importance of the aesthetic and technical guarantee here .

TRANSPORT AND STORAGE

  • In the case of collection by own means of transport, the car should have an open loading platform enabling easy loading and unloading.
  • At the construction site, panels should be stored in factory packaging, under a roof. Storage in such conditions should not exceed 3 weeks from the date of production. After this time, the packaging should be cut open and the sheets should be placed with spacers enabling free air circulation. The maximum storage time should not be longer than 6 months from the production date, otherwise the warranty will be void.
  • Protective films are used to additionally protect coated sheets against mechanical damage, stresses and impacts that may occur during transport, handling or profiling. Protective films never release the sheet from the obligation to properly protect the sheets during storage or against the harmful effects of chemical agents during their processing. It is recommended to gradually remove the foil from the finished profiles, element by element, before fixing the wall and roof elements to the building. Removal of the protective foil from the surface of the sheet should take place within three weeks from the date of sheet manufacture, if the goods are stored properly, i.e. with positive temperature, no high humidity, without direct sunlight.
  • Improper storage may cause difficulties in removing the protective film and leave traces of glue on the sheets.

MAINTENANCE AND WASHING

  • In order to extend the service life of roofs and facades made of coated metal sheets, they should be regularly inspected and maintained.
  • Inspection –  Once a year (preferably in spring), the roof / facade should be inspected for early detection of possible damage.
  • Sheet cleaning – Roofs / facades made of coated sheet metal require cleaning at least once a year. Dirt settling on the sheet can cause uneven discoloration (the result of uneven exposure to UV rays), and also reduce corrosion resistance (dirt retains moisture on the sheet and gradually damages it). Dirty and stained places can be cleaned with a soft brush and water (temperature max. 60 ° C). If necessary, it is allowed to add a mild detergent to the water (pH 6 ÷ 7, max. 10% solution). Pressurized water (max. 100 bar) can also be used for cleaning, however, the water jet should not be applied too close to the sheet surface (min. 30 cm), and should not be directed perpendicularly to the surface. At the connectors, the stream of water should be directed downwards so that to avoid the ingress of pressurized water into the gaps around the fittings. Old coatings should be handled with extreme care. Washing should be carried out from the top downwards and the cleaned area should be immediately and thoroughly rinsed with clean water.
  • Scouring powders, nitro solvents, chlorine solutions, aromatic agents as well as agents containing ammonium chloride or sodium salts must not be  used.
  • Damage – Repairing any damage during the warranty period should be consulted with the roof / facade contractor and may only be performed with his approval. Damage to small areas is repaired with air-drying repair varnishes. Painting large areas is, in principle, only possible with special industrial paints suitable for renovation of coverings. The surface to be painted should be limited only to the places that require it (scratches to the metal layer, corrosion centers, etc.). Preparation of the surface for painting should be performed according to generally accepted rules. Any signs of corrosion should always be thoroughly removed – preferably with special brushes or fine sandpaper. Then, the surface to be repaired must be thoroughly dusted, degreased and cleaned. To degrease the surface, you can use gasoline or water with the addition of surfactants (preferably with the addition of 1-2% ammonia solution). The areas to be repaired may show differences in color compared to the original colors of the sheets due to the natural influence of atmospheric phenomena (paint aging under the influence of UV radiation).
  • Organic coated steel sheets must not be  used in:
    • environment with constant contact with water with a high degree of salinity,
    • contact with construction chemicals, including concrete, plaster, wet wood, etc.,
    • in an environment exposed to aggressive chemicals
    • combination with materials with a different electrochemical potential
  • CAUTION – During inspection, cleaning, maintenance and repairs, safety rules must be strictly adhered to.

COLOR

The colors below may differ from reality.

Polyester gloss 25 um
RAL 9010 ***RAL 9010 ***
RAL 9002 **RAL 9002 **
RAL 7035 **RAL 7035 **
RAL 9006 ***RAL 9006 ***
RAL 9007 **RAL 9007 **
RAL 7000 *RAL 7000 *
RAL 7024 *RAL 7024 *
RAL 7016 **RAL 7016 **
RAL 5010 **RAL 5010 **
RAL 6029 **RAL 6029 **
RAL 6005 *RAL 6005 *
RAL 1021 *RAL 1021 *
RAL 1002 **RAL 1002 **
RAL 1015 *RAL 1015 *
RAL 8023 *RAL 8023 *
RAL 8004 *RAL 8004 *
RAL 3016 **RAL 3016 **
RAL 3005 *RAL 3005 *
RR 028 *RR 028 *
RAL 3011 **RAL 3011 **
RAL 8017 **RAL 8017 **
RR 032 *RR 032 *
RAL 9005 *RAL 9005 *
Golden Oak*Golden Oak*
PMG 35 um 8
PMG C. WalnutPMG C. Walnut
PMG RR 011PMG RR 011
PMG RR 028PMG RR 028
PMG RR 032PMG RR 032
PMG RAL 8017PMG RAL 8017
PMG RR 033PMG RR 033
PMG RAL 7016PMG RAL 7016
TOPMAT 35 um
TOPMAT RR 750TOPMAT RR 750
TOPMAT RAL 8017TOPMAT RAL 8017
TOPMAT RR 033TOPMAT RR 033
TOPMAT RAL 7016TOPMAT RAL 7016
Hybrid coating – PURMAX 40 um
RAL 8004RAL 8004
RAL 8017RAL 8017
RAL 7016RAL 7016
RAL 9005RAL 9005
Polyurethane – PURLAK 50 um
PU RAL 8004PU RAL 8004
PU RR 028PU RR 028
PU RAL 8017PU RAL 8017
PU RAL 9005PU RAL 9005
PU RAL 7016PU RAL 7016
Polyurethane – PURMAT 50 um
PUM RR 750PUM RR 750
PUM RR 011PUM RR 011
PUM RR 028PUM RR 028
PUM RAL 8017PUM RAL 8017
PUM RR 033PUM RR 033
PUM RAL 7016PUM RAL 7016
+


    Pasirinkti failusPrisegti failą

    Užsiprenumeruokite naujienlaiškį
    +
    Gaukite geriausius pasiūlymus, informaciją apie akcijas ir naujienas pirmieji.